High Resolution peripheral Quantitative Computed Tomography (HR-pQCT)

The XtremeCT II HR-pQCT scanner from SCANCO Medical is available for COMIRB-approved clinical research studies!

High Resolution peripheral Quantitative Computed Tomography (HR-pQCT) is now available to obtain non-invasive 3D images at the distal tibia and distal radius of humans for clinical in vivo assessments of volumetric bone mineral density and parameters of bone quality (e.g., microarchitecture, geometry, porosity, and biomechanics). XtremeCT II HR-pQCT scanner images have a very small isotropic voxel size (60.7 μm) and very low radiation dose (≤5 μSv per scan/anatomical site) so the device can be used for studies performed in adult, adolescent, and pediatric populations.


Key features of the HR-pQCT scanner include:

  • The HR-pQCT imaging device assesses bone microarchitecture at the distal tibia and distal radius
  • Bone microstructure measured by HR-pQCT contributes to fracture risk independently of aBMD obtained from DXA (Nishiyama et al. Curr Osteo Rep 2013)
  • Greater precision with this second-generation device means you can detect smaller changes in a shorter time frame than with other bone imaging modalities such as DXA
  • This research imaging modality is safe enough to use in pediatric and adolescent populations

The XtremeCT II is located on the sixth floor of the AHSB.

If your project is already funded, please fill out the Energy Balance Assessment Core (EBAC) Application to request services for your new project:

EBAC Application

The HR-pQCT device was acquired via successful grant applications to the NIGMS (S10 OD028453) and the University of Colorado’s Strategic Infrastructure for Research Committee (SIRC) in 2019.

Please remember to cite this grant (S10 OD028453) in any publication that utilized the HR-pQCT device!

Table 1. Most relevant bone parameters automatically computed by the HR-pQCT software
Density
Total volumetric bone mineral density (Total.vBMD; mg HA/cm3)Ratio of peripheral to mesial Tb.vBMD (p/m Tb.vBMD)
Trabecular volumetric bone mineral density (Tb.vBMD; mg HA/cm3)Cortical volumetric bone mineral density (Ct.vBMD; mg HA/cm3)
Peripheral trabecular volumetric bone mineral density (pTb.vBMD; mg HA/cm3)Cortical tissue mineral density (Ct.TMD; mg HA/cm3)
Mesial trabecular volumetric bone mineral density (mTb.vBMD; mg HA/cm3) 
Geometry
Total cross-sectional area (Tt.Ar; mm2)Trabecular volume (Tb.TV; mm3)
Trabecular cross-sectional area (Tb.Ar; mm2)Cortical volume (Ct.TV; mm3)
Cortical cross-sectional area (Ct.Ar; mm2)Cortical perimeter (Ct.Pm; mm)
Total tissue volume (Tt.TV; mm3) 
Trabecular bone microarchitecture
Bone volume fraction (BV/TV; %)Trabecular bone separation (Tb.Sp; µm)
Trabecular bone number (Tb.N; mm-1)Trabecular bone distribution (Tb.Sp.SD; µm)
Trabecular bone thickness (Tb.Th; µm) 
Cortical bone microstructure
Cortical bone thickness (Ct.Th; mm)Cortical pore volume (Ct.Po.V; mm3)
Cortical porosity (Ct.Po; %)Cortical pore diameter (Ct.Po.Dm; µm)
 Cortical pore diameter distribution (Ct.Po.Dm.SD; µm)
Bone biomechanics
Bone stiffness (kN/mm)Failure load (N)